Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Allied Health Professionals’ Corner
Author Reply
Book Review
Brief Communication
Case Report
Case Series
Clinical Case Report
Clinicopathological Conference
Commentary
Corrigendum
Editorial
Editorial – World Kidney Day 2016
Editorial Commentary
Erratum
Foreward
Guideline
Guidelines
Image in Nephrology
Images in Nephrology
In-depth Review
Letter to Editor
Letter to the Editor
Letter to the Editor – Authors’ reply
Letters to Editor
Literature Review
Nephrology in India
Notice of Retraction
Obituary
Original Article
Patient’s Voice
Perspective
Research Letter
Retraction Notice
Review
Review Article
Short Review
Special Article
Special Feature
Special Feature - World Kidney Day
Systematic Review
Technical Note
Varia
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Allied Health Professionals’ Corner
Author Reply
Book Review
Brief Communication
Case Report
Case Series
Clinical Case Report
Clinicopathological Conference
Commentary
Corrigendum
Editorial
Editorial – World Kidney Day 2016
Editorial Commentary
Erratum
Foreward
Guideline
Guidelines
Image in Nephrology
Images in Nephrology
In-depth Review
Letter to Editor
Letter to the Editor
Letter to the Editor – Authors’ reply
Letters to Editor
Literature Review
Nephrology in India
Notice of Retraction
Obituary
Original Article
Patient’s Voice
Perspective
Research Letter
Retraction Notice
Review
Review Article
Short Review
Special Article
Special Feature
Special Feature - World Kidney Day
Systematic Review
Technical Note
Varia
View/Download PDF

Translate this page into:

Letter to the Editor
ARTICLE IN PRESS
doi:
10.25259/IJN_732_2024

Continuous Glucose Monitoring in a Renal Transplant Setting

Department of Nephrology, SRM Medical College and Research Centre, SRMIST, Kattankulathur, Tamil Nadu, India
Department of General Medicine, SRM Medical College and Research Centre, SRMIST, Kattankulathur, Tamil Nadu, India

Corresponding author: Varadharajan Jayaprakash, Department of Nephrology, SRM Medical College and Research Centre, SRMIST, Kattankulathur, Tamil Nadu, India. E-mail: jayaprakash2k@gmail.com

Licence
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

How to cite this article: Arunkumar A, Jayaprakash V, Lamech TM, Kumar JS. Continuous Glucose Monitoring in a Renal Transplant Setting. Indian J Nephrol. doi: 10.25259/IJN_732_2024

Dear Editor,

A 31-year-old female with type 2 diabetes mellitus underwent kidney transplant surgery. Immediately post-operation, a continuous glucose sensor (Abbott, freestyle libre) was placed over the right deltoid region. The reader, a small mobile-phone-like device provided with the sensor was used to measure blood glucose levels. Glucose values were obtained by placing the reader over the sensor. We measured glucose levels hourly for the initial two days, and continuous insulin infusion (Human Actrapid) was administered for glycemic control. Subsequently, glucose levels were monitored every 4 hours, and as per requirement, a long- acting insulin preparation, Solo-star was administered at night. Human actrapid was also given thrice daily before meals as bolus dose, as per requirement. Her postoperative period was uneventful, and she was discharged with a serum creatinine of 0.8 mg/dL. Post-discharge continuous glucose monitoring (CGM) was not required, as her glycemic control had improved.

CGM is a great innovation, especially for those with erratic and fluctuating insulin requirements.1 It uses its subcutaneous sensors to estimate interstitial fluid glucose levels (usually every 5 minutes) throughout the day and wirelessly transmits the measured real-time data to the reader. This avoids the hassle of finger pricks. Two types are available: intermittently scanned CGM and real-time CGM (rt-CGM). We used the rt-CGM apparatus, which provided data including the time-in-target range, glycemic variability, and glucose management indicator [Figure 1]. The cost of CGM was the same as that of finger-test glucose monitoring.

Glycemic metrics of the patient. The colour codes indicate the degree of glucose control. Green indicates good control and red indicates suboptimal control. Mean glucose levels. The symbol indicates that the device was active and measurement was done for specified number of times. Blue color indicates the time period when sensor was active.
Figure 1:
Glycemic metrics of the patient. The colour codes indicate the degree of glucose control. Green indicates good control and red indicates suboptimal control. Mean glucose levels. The symbol indicates that the device was active and measurement was done for specified number of times. Blue color indicates the time period when sensor was active.

Clinical practice recommendations on glycemic control in renal transplant settings are currently unavailable.2,3 Jandovitz et al. conducted a randomized control trial comparing finger-test glucose monitoring with CGM for 40 diabetic patients with ESRD undergoing renal transplantation. Clinical outcomes were better in the CGM group.4

Conflicts of interest

There are no conflicts of interest.

References

  1. , . Application and management of continuous glucose monitoring in diabetic kidney disease. World J Diabetes. 2024;15:591-7.
    [CrossRef] [PubMed] [PubMed Central] [Google Scholar]
  2. . KDIGO 2022 Clinical practice guideline for diabetes management in chronic kidney disease. Kidney Int. 2022;102:S1-S127.
    [CrossRef] [PubMed] [Google Scholar]
  3. , , , , , , et al. KDIGO Clinical practice guideline on the evaluation and management of candidates for kidney transplantation. Transplantation. 2020;104:S11-S103.
    [CrossRef] [PubMed] [Google Scholar]
  4. , , , , , , et al. A randomized trial of continuous glucose monitoring to improve post-transplant glycemic control. Clin Transplant. 2023;37:e15139.
    [CrossRef] [PubMed] [Google Scholar]

Fulltext Views
187

PDF downloads
500
View/Download PDF
Download Citations
BibTeX
RIS
Show Sections